The heated print bed with a borosilicate glass print surface.
To remove the print bed assembly.
Disconnect the heater and temperature sensor.
Print bed disconnected.
Un-hook the 4 springs.
Un hook springs.
Un hooked spring.
Once all spring are un hooked.
Lift the print bed assembly off the lift platform.
Print bed assembly removed from lift platform.
Front right 50x6mm grub screw - Print bed support.
Back center 50x6mm grub screw - Print bed support.
To re-install the print bed assembly.
Lay the print bed assembly onto the 3 pointed 50x6mm grub crews, take care the grub-screw- points locate to the holes of the print bed assembly.
Use a wire to grab, stretch and engage the 4 springs
Spring re-installed.
Re connect the heater and temperature sensor.
Level the print-bed wth the 3 M6x50mm grub screws.